Coil and furnace lining replacement


Coil replacement

  After stopping the gas and exhaust, remove the two thermocouple connectors connected to the lower part, close the water valve of the coil, change the cable to use a plum wrench or socket wrench, cable wiring to face contact, not point or line contact.

图片25.png    图片26.png


Furnace lining replacement

  Move the heating coil to a place where it is easy to assemble. When moving the inner sleeve out of the heating coil, be careful not to rub with the coil, apply the insulating material with insulating paint to the damage, repeat twice, put the new inner sleeve into the heating coil, also be careful not to rub with the coil, put the heating coil, after each group of temperature sensors are installed, remove the insulating paper between the inner sleeve and each group of temperature sensors.

图片27.png